Central Air Conditioning Refrigerant Pressure Sensor
Product parameters
1. Key Technical Specifications
Working pressure: 0~2.0MPa (range can be adjusted)
Precision: ±1.5%F.S. (linearity, hysteresis, repeatability)
Total error band: ±3.0%F.S. (-30℃~+100℃)
A high-precision version is also available
Operating temperature: -30℃~+100℃
Storage temperature: -40℃~+120℃
Protection pressure: 4.0Mpa
Burst pressure: 6.0Mpa
Working medium: R22, R407C, R134A and other refrigerants
Service life: five million full range cycles
Vibration: 11g (20~2000Hz)
Electrical interface: YAZAKI RK03FB
Protection level: IP69K
Shell material: 304 stainless steel
Pressure connection: φ6*1.0 pipe connection
Supply voltage: 5.0±0.25VDC
Output voltage: 0.5~4.5VDC (adjustable in 5V range)
Power supply current: 10mA(Max)
Load impedance: 10KΩ (typical)
Output response time: 3mS
Overvoltage protection: 16VDC
Reverse voltage: -14VDC
Short circuit protection: Yes
EMC (80MHz to 1000MHz) : 3V/m
ESD: 15KV air contact 8KV terminal 2KV
2. Core Function
Continuously monitor refrigerant pressure of high and low pressure circuits while the air conditioner is running.
Over-high pressure protection: Automatically shut down the compressor to prevent pipeline crack and compressor burnout.
Over-low pressure protection: Cut off compressor operation to avoid dry burning due to refrigerant leakage.
Deliver pressure data to the controller to adjust fan speed, compressor frequency and electronic expansion valve opening for stable cooling output.
Built-in self-diagnosis module identifies open circuits, short circuits and abnormal pressure values, sends out fault alarm signals and stores fault codes.
3. Working Principle
This sensor adopts mature piezoresistive sensing technology:
Refrigerant pressure pushes the corrosion-resistant metal sensitive diaphragm and creates tiny elastic deformation.
Integrated strain resistors on the diaphragm generate linear resistance changes corresponding to pressure values.
The Wheatstone bridge converts resistance fluctuations into standard analog voltage signals.
Internal signal conditioning and temperature compensation circuits eliminate environmental interference and output stable signals to the equipment controller.
4. Application Scope
Equipment Types
Water-cooled chillers, air-cooled heat pumps, rooftop commercial air conditioners, data center precision air conditioners, supermarket and shopping mall refrigeration units.
Application Scenarios
Central air conditioning systems for office buildings, constant temperature cooling for factories, heat dissipation of data centers, cold storage equipment for catering and large public refrigeration facilities.
Dimensions
This product can be customized for customers. All types of our temperature sensors are available for customized service. Welcome to consult our sales staff for more details and product catalogs.